For a better checkout experience, please try our new website.
/Products/Electric Motors/3 Phase/WEG 3-Phase Electric Motors/Cast Iron, ODP, W40/Foot Mount, C-Face/02012OT3E286TC-W40 WEG 20HP, General Purpose Electric Motor, 1200RPM

Product ID: 02012OT3E286TC-W40

02012OT3E286TC-W40 WEG 20HP, General Purpose Electric Motor, 1200RPM

MFG: WEG Electric Corporation
MFG Part Number: 02012OT3E286TC-W40

Selected accessories will also be added to cart
$2,775.91 / Each
Quantity:
IC01 - ODP, IP23, 284TC/286TC Frame, 230/460/380VAC 50/60Hz 3 Phase, 14494187, NEMA Premium Efficiency, Foot Mounted, C-Face, Cast Iron Frame, 1-7/8" Keyed Shaft

Electric Motors

Frame284/6TC
Output20 HP (15 kW)
Number of Poles6
Frequency60 Hz
Rated speed1177 rpm
Slip1.92 %
Rated voltage230/460 V
Rated current48.6/24.3 A
L. R. Amperes311/156 A
LRC6.4x(Code G)
No load current18.8/9.40 A
Rated torque89.2 ft.lb
Locked rotor torque229 %
Breakdown torque260 %
Locked rotor time27s (cold) 15s (hot)
Moment of inertia (J)6.89 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.25
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP23
EnclosureIC01 - ODP
MountingF-1
Rotation?Both (CW and CCW)
Noise level?59.0 dB(A)
Approx. weight?392 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
91.7  92.4  92.4 

Power factor

50%75%100%
0.71  0.80  0.84 
Frame284/6TC
Output15 HP (11 kW)
Number of Poles6
Frequency50 Hz
Rated speed980 rpm
Slip2.00 %
Rated voltage380 V
Rated current22.0 A
L. R. Amperes158 A
LRC7.2x(Code H)
No load current9.30 A
Rated torque80.4 ft.lb
Locked rotor torque270 %
Breakdown torque280 %
Locked rotor time28s (cold) 16s (hot)
Moment of inertia (J)6.89 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP23
EnclosureIC01 - ODP
MountingF-1
Rotation?Both (CW and CCW)
Noise level?59.0 dB(A)
Approx. weight?392 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
89.9  90.3  90.3 

Power factor

50%75%100%
0.68  0.79  0.84 
Frame284/6TC
Output15 HP (11 kW)
Number of Poles6
Frequency50 Hz
Rated speed980 rpm
Slip2.00 %
Rated voltage400 V
Rated current21.4 A
L. R. Amperes161 A
LRC7.5x(Code J)
No load current10.0 A
Rated torque80.4 ft.lb
Locked rotor torque310 %
Breakdown torque320 %
Locked rotor time28s (cold) 16s (hot)
Moment of inertia (J)6.89 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP23
EnclosureIC01 - ODP
MountingF-1
Rotation?Both (CW and CCW)
Noise level?59.0 dB(A)
Approx. weight?392 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
89.9  90.3  90.3 

Power factor

50%75%100%
0.64  0.76  0.82 
Frame284/6TC
Output15 HP (11 kW)
Number of Poles6
Frequency50 Hz
Rated speed984 rpm
Slip1.60 %
Rated voltage415 V
Rated current20.9 A
L. R. Amperes157 A
LRC7.5x(Code J)
No load current10.5 A
Rated torque80.0 ft.lb
Locked rotor torque340 %
Breakdown torque340 %
Locked rotor time28s (cold) 16s (hot)
Moment of inertia (J)6.89 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP23
EnclosureIC01 - ODP
MountingF-1
Rotation?Both (CW and CCW)
Noise level?59.0 dB(A)
Approx. weight?392 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
89.9  90.3  90.3 

Power factor

50%75%100%
0.62  0.74  0.81 

Features

Frame MaterialCast Iron 
Impregnation MethodDip and Bake Polyester 
Regreasing SystemAt Drive end and Non-drive end 
Main terminal box holeNPT 1 1/2" 
Terminal BlockWithout 
Shaft Locking DeviceWithout 
Shaft MaterialSAE 1040/45 Carbon Steel 
PaintingRAL 5009 203A (ISO 12944 - C2) 
Grounding LugsSingle 
Fan Cover materialWithout Fan Cover 
Tropicalized PaintingWithout 
Fan materialWithout fan 
Bearing capYes- Bearing Cap 
Bolt MaterialCarbon Steel 
Balancing Method1/2 Key 
Drip CoverWithout 
Overload protector (phenolic)Without overload protector  
Connection Cables Quantity12 
Type
Electric Motor
Input Phase
3-Phase
Speed
1200RPM
Horsepower
20HP
Enclosure
ODP
Frame
284TC/286TC