For a better checkout experience, please try our new website.
/Products/Electric Motors/3 Phase/WEG 3-Phase Electric Motors/W22 General Purpose, TEFC/Foot Mount/02518ET3E284T-W22 WEG 25HP Severe Duty Electric Motor, 1800RPM

Product ID: 02518ET3E284T-W22

02518ET3E284T-W22 WEG 25HP Severe Duty Electric Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: 02518ET3E284T-W22

Selected accessories will also be added to cart
$2,441.27 / Each
Quantity:
IC411 - TEFC, IP55, 284T/286T Frame, 208-230/460VAC 60Hz 3 Phase, 12424790, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 1-7/8" Shaft

Electric Motors

Frame 284/6T
Output 25 HP (18.5 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1765 rpm
Slip 1.94 %
Rated voltage 208-230/460 V
Rated current 65.2-59.0/29.5 A
L. R. Amperes 404-366/183 A
LRC 6.2x(Code G)
No load current 18.1-21.0/10.5 A
Rated torque 73.4 ft.lb
Locked rotor torque 240 %
Breakdown torque 270 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 5.11 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 413 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.6 

Power factor

50% 75% 100%
0.70  0.80  0.84 
Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 380 V
Rated current 29.1 A
L. R. Amperes 175 A
LRC 6.0x(Code G)
No load current 10.4 A
Rated torque 70.7 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 5.11 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 413 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.3  92.1  92.1 

Power factor

50% 75% 100%
0.69  0.80  0.85 
Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 28.2 A
L. R. Amperes 189 A
LRC 4.9x(Code E)
No load current 11.1 A
Rated torque 70.5 ft.lb
Locked rotor torque 260 %
Breakdown torque 300 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 5.11 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 413 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.3  92.5  92.6 

Power factor

50% 75% 100%
0.65  0.78  0.83 
Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 27.5 A
L. R. Amperes 198 A
LRC 5.5x(Code F)
No load current 11.6 A
Rated torque 70.5 ft.lb
Locked rotor torque 290 %
Breakdown torque 330 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 5.11 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 413 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.2  92.5  92.7 

Power factor

50% 75% 100%
0.62  0.75  0.82 
Frame 284/6T
Output 25 HP (18.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1445 rpm
Slip 3.67 %
Rated voltage 380 V
Rated current 35.6 A
L. R. Amperes 174 A
LRC 6.2x(Code G)
No load current 10.4 A
Rated torque 89.6 ft.lb
Locked rotor torque 180 %
Breakdown torque 210 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 5.11 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 413 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  91.7  91.7 

Power factor

50% 75% 100%
0.76  0.84  0.86 
Frame 284/6T
Output 25 HP (18.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1455 rpm
Slip 3.00 %
Rated voltage 400 V
Rated current 34.0 A
L. R. Amperes 187 A
LRC 6.2x(Code G)
No load current 11.1 A
Rated torque 89.0 ft.lb
Locked rotor torque 210 %
Breakdown torque 240 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 5.11 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 413 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  92.4  92.4 

Power factor

50% 75% 100%
0.73  0.82  0.85 
Frame 284/6T
Output 25 HP (18.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 415 V
Rated current 33.2 A
L. R. Amperes 196 A
LRC 6.2x(Code G)
No load current 11.6 A
Rated torque 88.7 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 5.11 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 413 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  92.4  92.4 

Power factor

50% 75% 100%
0.70  0.80  0.84 
Type
Electric Motor
Input Phase
3-Phase
Speed
1800RPM
Application
Severe Duty
Horsepower
25HP
Enclosure
TEFC
Enclosure
TEFC
Input Voltage
208VAC
Input Voltage
208VAC
Input Voltage
230VAC
Input Voltage
230VAC
Input Voltage
460VAC
Input Voltage
460VAC
Frame
284T/286T