IC411-TEFC, IP55, 284T/286T Frame, 208-230/460VAC 60Hz 3-Phase, 11443945, Foot Mounted, Cast Iron Frame, NEMA Premium Efficiency, 1-7/8" Keyed Shaft

Electric Motors

Frame284/6T
Output30 HP (22 kW)
Number of Poles4
Frequency60 Hz
Rated speed1765 rpm
Slip1.94 %
Rated voltage208-230/460 V
Rated current77.6-70.2/35.1 A
L. R. Amperes474-428/214 A
LRC6.1x(Code G)
No load current22.4-26.0/13.0 A
Rated torque88.1 ft.lb
Locked rotor torque240 %
Breakdown torque240 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)5.85 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.25
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?63.0 dB(A)
Approx. weight?451 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
93.0  93.0  93.6 

Power factor

50%75%100%
0.70  0.80  0.84 
Frame284/6T
Output25 HP (18.5 kW)
Number of Poles4
Frequency50 Hz
Rated speed1465 rpm
Slip2.33 %
Rated voltage380 V
Rated current35.7 A
L. R. Amperes214 A
LRC6.0x(Code G)
No load current12.9 A
Rated torque88.4 ft.lb
Locked rotor torque220 %
Breakdown torque250 %
Locked rotor time27s (cold) 15s (hot)
Moment of inertia (J)5.85 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?61.0 dB(A)
Approx. weight?451 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
92.1  92.5  92.6 

Power factor

50%75%100%
0.70  0.81  0.85 
Frame284/6T
Output25 HP (18.5 kW)
Number of Poles4
Frequency50 Hz
Rated speed1465 rpm
Slip2.33 %
Rated voltage400 V
Rated current34.0 A
L. R. Amperes228 A
LRC6.1x(Code G)
No load current13.8 A
Rated torque88.4 ft.lb
Locked rotor torque250 %
Breakdown torque290 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)5.85 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?61.0 dB(A)
Approx. weight?451 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
92.1  92.8  92.7 

Power factor

50%75%100%
0.67  0.79  0.84 
Frame284/6T
Output25 HP (18.5 kW)
Number of Poles4
Frequency50 Hz
Rated speed1465 rpm
Slip2.33 %
Rated voltage415 V
Rated current33.6 A
L. R. Amperes235 A
LRC6.1x(Code G)
No load current14.5 A
Rated torque88.4 ft.lb
Locked rotor torque280 %
Breakdown torque310 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)5.85 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?61.0 dB(A)
Approx. weight?451 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
91.6  92.5  92.6 

Power factor

50%75%100%
0.64  0.76  0.82 
Frame284/6T
Output30 HP (22 kW)
Number of Poles4
Frequency50 Hz
Rated speed1455 rpm
Slip3.00 %
Rated voltage380 V
Rated current42.4 A
L. R. Amperes212 A
LRC6.1x(Code G)
No load current12.9 A
Rated torque107 ft.lb
Locked rotor torque180 %
Breakdown torque210 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)5.85 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise105 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?61.0 dB(A)
Approx. weight?451 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
92.4  92.4  91.7 

Power factor

50%75%100%
0.76  0.83  0.86 
Frame284/6T
Output30 HP (22 kW)
Number of Poles4
Frequency50 Hz
Rated speed1460 rpm
Slip2.67 %
Rated voltage400 V
Rated current40.4 A
L. R. Amperes226 A
LRC6.1x(Code G)
No load current13.8 A
Rated torque106 ft.lb
Locked rotor torque210 %
Breakdown torque240 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)5.85 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise105 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?61.0 dB(A)
Approx. weight?451 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
93.0  92.4  92.4 

Power factor

50%75%100%
0.73  0.82  0.85 
Frame284/6T
Output30 HP (22 kW)
Number of Poles4
Frequency50 Hz
Rated speed1460 rpm
Slip2.67 %
Rated voltage415 V
Rated current39.4 A
L. R. Amperes236 A
LRC6.1x(Code G)
No load current14.5 A
Rated torque106 ft.lb
Locked rotor torque229 %
Breakdown torque260 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)5.85 sq.ft.lb
DesignB
Insulation ClassF
Service factor1.00
Temperature rise105 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?61.0 dB(A)
Approx. weight?451 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
92.4  92.4  92.4 

Power factor

50%75%100%
0.70  0.80  0.84 
Type
Electric Motor
Input Phase
3-Phase
Speed
1800RPM
Application
Severe Duty
Horsepower
30HP
Enclosure
TEFC
Enclosure
TEFC
Input Voltage
208VAC
Input Voltage
208VAC
Input Voltage
230VAC
Input Voltage
230VAC
Input Voltage
460VAC
Input Voltage
460VAC
Frame
284T/286T