For a better checkout experience, please try our new website.
/Products/Electric Motors/3 Phase/WEG 3-Phase Electric Motors/W22 General Purpose, TEFC/Foot Mount/05018ET3E326T-W22 WEG 50HP Severe Duty Electric Motor, 1800RPM

Product ID: 05018ET3E326T-W22

05018ET3E326T-W22 WEG 50HP Severe Duty Electric Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: 05018ET3E326T-W22

Selected accessories will also be added to cart
$4,539.00 / Each
Quantity:
IC411-TEFC, IP55, 324T/326T Frame, 208-230/460VAC 60Hz 3 Phase, 11438076, Foot Mounted, Cast Iron Frame, 2-1/8" Keyed Shaft, NEMA Premium Efficiency

Electric Motors

Frame 324/6T
Output 50 HP (37 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1775 rpm
Slip 1.39 %
Rated voltage 208-230/460 V
Rated current 131-118/59.2 A
L. R. Amperes 812-734/367 A
LRC 7.0x(Code H)
No load current 40.5-47.0/23.5 A
Rated torque 146 ft.lb
Locked rotor torque 229 %
Breakdown torque 270 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.0  94.1  94.5 

Power factor

50% 75% 100%
0.66  0.77  0.83 
Frame 324/6T
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 58.7 A
L. R. Amperes 376 A
LRC 7.4x(Code J)
No load current 23.0 A
Rated torque 141 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.5  93.1  93.6 

Power factor

50% 75% 100%
0.64  0.77  0.83 
Frame 324/6T
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 57.1 A
L. R. Amperes 400 A
LRC 5.2x(Code E)
No load current 24.0 A
Rated torque 140 ft.lb
Locked rotor torque 250 %
Breakdown torque 300 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.5  92.8  93.6 

Power factor

50% 75% 100%
0.60  0.73  0.81 
Frame 324/6T
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1478 rpm
Slip 1.47 %
Rated voltage 415 V
Rated current 56.4 A
L. R. Amperes 417 A
LRC 5.8x(Code F)
No load current 25.0 A
Rated torque 140 ft.lb
Locked rotor torque 260 %
Breakdown torque 330 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.5  93.0  93.6 

Power factor

50% 75% 100%
0.57  0.70  0.79 
Frame 324/6T
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 380 V
Rated current 71.6 A
L. R. Amperes 372 A
LRC 6.2x(Code G)
No load current 23.0 A
Rated torque 177 ft.lb
Locked rotor torque 180 %
Breakdown torque 210 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.0  93.0  92.4 

Power factor

50% 75% 100%
0.72  0.81  0.85 
Frame 324/6T
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 400 V
Rated current 68.4 A
L. R. Amperes 397 A
LRC 7.0x(Code H)
No load current 24.0 A
Rated torque 177 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.0 

Power factor

50% 75% 100%
0.68  0.79  0.84 
Frame 324/6T
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 66.3 A
L. R. Amperes 411 A
LRC 7.0x(Code H)
No load current 25.0 A
Rated torque 176 ft.lb
Locked rotor torque 210 %
Breakdown torque 260 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.5 

Power factor

50% 75% 100%
0.65  0.76  0.83 
Type
Electric Motor
Input Phase
3-Phase
Speed
1800RPM
Application
Severe Duty
Horsepower
50HP
Enclosure
TEFC
Enclosure
TEFC
Input Voltage
208VAC
Input Voltage
208VAC
Input Voltage
230VAC
Input Voltage
230VAC
Input Voltage
460VAC
Input Voltage
460VAC
Frame
324T/326T