For a better checkout experience, please try our new website.
/Products/Electric Motors/3 Phase/WEG 3-Phase Electric Motors/Super Premium Efficiency/12512EG3G445T-W22 WEG 125HP Electric Motor, 1200RPM

Product ID: 12512EG3G445T-W22

12512EG3G445T-W22 WEG 125HP Electric Motor, 1200RPM

MFG: WEG Electric Corporation
MFG Part Number: 12512EG3G445T-W22

Selected accessories will also be added to cart
$17,570.38 / Each
Quantity:
IC411 - TEFC, IP55, 444T/445T Frame, 460VAC 60Hz 3 Phase, 11792523, Super Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-3/8" Keyed Shaft

Electric Motors

Frame444/5T
Output125 HP
Number of Poles6
Frequency60 Hz
Rated speed1190 rpm
Slip0.83 %
Rated voltage460 V
Rated current152 A
L. R. Amperes1155 A
LRC7.6x(Code J)
No load current72.0 A
Rated torque552 ft.lb
Locked rotor torque240 %
Breakdown torque260 %
Locked rotor time45s (cold) 25s (hot)
Moment of inertia (J)114 sq.ft.lb
DesignA
Insulation ClassF
Service factor1.25
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?69.0 dB(A)
Approx. weight?2061 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
95.0  95.8  95.8 

Power factor

50%75%100%
0.62  0.74  0.80 
Frame444/5T
Output125 HP
Number of Poles6
Frequency50 Hz
Rated speed985 rpm
Slip1.50 %
Rated voltage380 V
Rated current179 A
L. R. Amperes1074 A
LRC6.0x(Code G)
No load current71.0 A
Rated torque666 ft.lb
Locked rotor torque180 %
Breakdown torque210 %
Locked rotor time39s (cold) 22s (hot)
Moment of inertia (J)114 sq.ft.lb
DesignA
Insulation ClassF
Service factor1.25
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?65.0 dB(A)
Approx. weight?2061 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
94.6  95.0  95.0 

Power factor

50%75%100%
0.69  0.79  0.83 
Frame444/5T
Output125 HP
Number of Poles6
Frequency50 Hz
Rated speed990 rpm
Slip1.00 %
Rated voltage400 V
Rated current172 A
L. R. Amperes1118 A
LRC6.5x(Code G)
No load current76.0 A
Rated torque663 ft.lb
Locked rotor torque200 %
Breakdown torque240 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)114 sq.ft.lb
DesignA
Insulation ClassF
Service factor1.15
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?65.0 dB(A)
Approx. weight?2061 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
95.0  95.4  95.4 

Power factor

50%75%100%
0.65  0.76  0.82 
Frame444/5T
Output125 HP
Number of Poles6
Frequency50 Hz
Rated speed990 rpm
Slip1.00 %
Rated voltage415 V
Rated current170 A
L. R. Amperes1173 A
LRC6.9x(Code H)
No load current80.0 A
Rated torque663 ft.lb
Locked rotor torque220 %
Breakdown torque260 %
Locked rotor time36s (cold) 20s (hot)
Moment of inertia (J)114 sq.ft.lb
DesignA
Insulation ClassF
Service factor1.15
Temperature rise80 K
Duty CycleCont.(S1)
Starting MethodDirect On Line
Ambient temperature-20?C to +40?C
Altitude1000 m.a.s.l.
Degree of ProtectionIP55
EnclosureIC411 - TEFC
MountingF-1
Rotation?Both (CW and CCW)
Noise level?65.0 dB(A)
Approx. weight?2061 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50%75%100%
95.0  95.4  95.4 

Power factor

50%75%100%
0.62  0.74  0.80 

Features

Frame MaterialCast Iron 
Impregnation MethodConstant Resin Flow 
Regreasing SystemAt Drive end and Non-drive end 
Main terminal box hole2xNPT 3" 
Terminal BlockWithout 
Shaft Locking DeviceWithout 
DrainRubber, automatic 
Shaft MaterialSAE 4140 Carbon Steel 
PaintingRAL 6002 203A (ISO 12944 - C2) 
Grounding LugsDouble 
Fan Cover materialCast Iron 
Tropicalized PaintingWithout 
Fan materialPlastic 
Bearing capYes- Bearing Cap 
Balancing Method1/2 Key 
Drip CoverWithout 
Overload protector (phenolic)Without overload protector  
Connection Cables Quantity12 
Type
Electric Motor
Input Phase
3-Phase
Speed
1200RPM
Enclosure
TEFC
Enclosure
TEFC
Horsepower
125HP
Input Voltage
460VAC
Frame
444T/445T