IC411 - TEFC, IP55, 444TS/445TS Frame, 460VAC 60Hz 3 Phase, 11485814, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame

Electric Motors

Frame 444/5TS
Output 150 HP (110 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3570 rpm
Slip 0.83 %
Rated voltage 460 V
Rated current 161 A
L. R. Amperes 1129 A
LRC 7.0x(Code G)
No load current 39.0 A
Rated torque 221 ft.lb
Locked rotor torque 200 %
Breakdown torque 250 %
Locked rotor time 55s (cold) 31s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 86.0 dB(A)
Approx. weight³ 2182 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  95.0  95.4 

Power factor

50% 75% 100%
0.85  0.89  0.90 
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 380 V
Rated current 161 A
L. R. Amperes 1063 A
LRC 6.6x(Code F)
No load current 38.5 A
Rated torque 221 ft.lb
Locked rotor torque 190 %
Breakdown torque 240 %
Locked rotor time 45s (cold) 25s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 83.0 dB(A)
Approx. weight³ 2182 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  94.1  94.5 

Power factor

50% 75% 100%
0.85  0.89  0.90 
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2975 rpm
Slip 0.83 %
Rated voltage 400 V
Rated current 153 A
L. R. Amperes 1117 A
LRC 7.3x(Code G)
No load current 41.0 A
Rated torque 221 ft.lb
Locked rotor torque 200 %
Breakdown torque 270 %
Locked rotor time 45s (cold) 25s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 83.0 dB(A)
Approx. weight³ 2182 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  94.5  95.1 

Power factor

50% 75% 100%
0.83  0.88  0.89 
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2975 rpm
Slip 0.83 %
Rated voltage 415 V
Rated current 148 A
L. R. Amperes 1169 A
LRC 7.9x(Code H)
No load current 43.0 A
Rated torque 221 ft.lb
Locked rotor torque 229 %
Breakdown torque 290 %
Locked rotor time 45s (cold) 25s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 83.0 dB(A)
Approx. weight³ 2182 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  94.5  95.0 

Power factor

50% 75% 100%
0.81  0.87  0.89 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Sinterized, Exd 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 202P (ISO 12944 - C4) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Aluminum 
Bearing cap Yes- Bearing Cap 
Bolt Material Carbon Steel 
Winding thermal protection Thermostat - 2 wires 1 per phase 155°C 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12