/Products/Electric Motors/3 Phase/WEG/Crusher Duty/20012ET3GRB447T-W22 WEG 200HP Crusher Duty Electric Motor, 1200RPM

Product ID: 20012ET3GRB447T-W22

20012ET3GRB447T-W22 WEG 200HP Crusher Duty Electric Motor, 1200RPM

MFG: WEG Electric Corporation
MFG Part Number: 20012ET3GRB447T-W22

Selected accessories will also be added to cart
$18,849.75 / Each
Quantity:
IC411 - TEFC, IP55, 445T/447T Frame, 460VAC 60Hz 3 Phase, 11546823, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-3/8" Keyed Shaft

Electric Motors

Frame 445/7T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1185 rpm
Slip 1.25 %
Rated voltage 460 V
Rated current 237 A
L. R. Amperes 1493 A
LRC 6.3x(Code G)
No load current 100 A
Rated torque 886 ft.lb
Locked rotor torque 229 %
Breakdown torque 240 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2510 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.4  95.8 

Power factor

50% 75% 100%
0.68  0.79  0.83 
Frame 445/7T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 380 V
Rated current 214 A
L. R. Amperes 1391 A
LRC 6.5x(Code G)
No load current 98.9 A
Rated torque 800 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2510 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  95.1  95.1 

Power factor

50% 75% 100%
0.65  0.76  0.82 
Frame 445/7T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 400 V
Rated current 209 A
L. R. Amperes 1505 A
LRC 7.2x(Code H)
No load current 106 A
Rated torque 800 ft.lb
Locked rotor torque 250 %
Breakdown torque 280 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2510 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  95.1  95.1 

Power factor

50% 75% 100%
0.62  0.74  0.80 
Frame 445/7T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 204 A
L. R. Amperes 1571 A
LRC 7.7x(Code J)
No load current 111 A
Rated torque 800 ft.lb
Locked rotor torque 270 %
Breakdown torque 310 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2510 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  95.1  95.1 

Power factor

50% 75% 100%
0.59  0.71  0.79 
Frame 445/7T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 285 A
L. R. Amperes 1425 A
LRC 5.0x(Code E)
No load current 98.9 A
Rated torque 1070 ft.lb
Locked rotor torque 180 %
Breakdown torque 190 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2510 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  94.5  94.0 

Power factor

50% 75% 100%
0.74  0.83  0.85 
Frame 445/7T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 273 A
L. R. Amperes 1529 A
LRC 5.6x(Code F)
No load current 106 A
Rated torque 1070 ft.lb
Locked rotor torque 200 %
Breakdown torque 210 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2510 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  94.5  94.5 

Power factor

50% 75% 100%
0.71  0.81  0.84 
Frame 445/7T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 265 A
L. R. Amperes 1590 A
LRC 6.0x(Code G)
No load current 111 A
Rated torque 1070 ft.lb
Locked rotor torque 220 %
Breakdown torque 229 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2510 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.0  94.5  95.0 

Power factor

50% 75% 100%
0.68  0.79  0.83 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device With 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12