We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/25036ET3G447TS-W22 WEG 250HP Severe Duty Electric Motor, 3600RPM

Product ID: 25036ET3G447TS-W22

25036ET3G447TS-W22 WEG 250HP Severe Duty Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 25036ET3G447TS-W22

Selected accessories will also be added to cart
$22,384.50 / Each
Quantity:
IC411 - TEFC, IP55, 445TS/447TS Frame, 460VAC 60Hz 3 Phase, 11438014, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 2-3/8" Keyed Shaft

Electric Motors

Frame 445/7TS
Output 250 HP (185 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3573 rpm
Slip 0.75 %
Rated voltage 460 V
Rated current 269 A
L. R. Amperes 1802 A
LRC 6.7x(Code G)
No load current 60.0 A
Rated torque 367 ft.lb
Locked rotor torque 210 %
Breakdown torque 240 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 50.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2303 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.8  95.8 

Power factor

50% 75% 100%
0.84  0.89  0.90 
Frame 445/7TS
Output 200 HP (150 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2973 rpm
Slip 0.90 %
Rated voltage 380 V
Rated current 265 A
L. R. Amperes 1776 A
LRC 6.7x(Code G)
No load current 60.0 A
Rated torque 353 ft.lb
Locked rotor torque 190 %
Breakdown torque 240 %
Locked rotor time 48s (cold) 27s (hot)
Moment of inertia (J) 50.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2303 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.6  95.6 

Power factor

50% 75% 100%
0.84  0.89  0.90 
Frame 445/7TS
Output 200 HP (150 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2977 rpm
Slip 0.77 %
Rated voltage 400 V
Rated current 252 A
L. R. Amperes 1865 A
LRC 7.4x(Code H)
No load current 65.0 A
Rated torque 353 ft.lb
Locked rotor torque 210 %
Breakdown torque 270 %
Locked rotor time 45s (cold) 25s (hot)
Moment of inertia (J) 50.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2303 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.1  95.6  95.6 

Power factor

50% 75% 100%
0.82  0.88  0.90 
Frame 445/7TS
Output 200 HP (150 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2979 rpm
Slip 0.70 %
Rated voltage 415 V
Rated current 245 A
L. R. Amperes 2034 A
LRC 8.3x(Code J)
No load current 70.0 A
Rated torque 353 ft.lb
Locked rotor torque 220 %
Breakdown torque 300 %
Locked rotor time 41s (cold) 23s (hot)
Moment of inertia (J) 50.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2303 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.1  95.6  95.6 

Power factor

50% 75% 100%
0.80  0.87  0.89 
Frame 445/7TS
Output 250 HP (185 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2962 rpm
Slip 1.27 %
Rated voltage 380 V
Rated current 330 A
L. R. Amperes 1782 A
LRC 5.4x(Code E)
No load current 60.0 A
Rated torque 443 ft.lb
Locked rotor torque 160 %
Breakdown torque 190 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 50.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2303 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.0  94.5 

Power factor

50% 75% 100%
0.87  0.90  0.90 
Frame 445/7TS
Output 250 HP (185 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2967 rpm
Slip 1.10 %
Rated voltage 400 V
Rated current 312 A
L. R. Amperes 1903 A
LRC 6.1x(Code F)
No load current 65.0 A
Rated torque 442 ft.lb
Locked rotor torque 170 %
Breakdown torque 220 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 50.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2303 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.4  95.0 

Power factor

50% 75% 100%
0.85  0.89  0.90 
Frame 445/7TS
Output 250 HP (185 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 300 A
L. R. Amperes 2010 A
LRC 6.7x(Code G)
No load current 70.0 A
Rated torque 442 ft.lb
Locked rotor torque 180 %
Breakdown torque 229 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 50.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2303 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.8  95.4 

Power factor

50% 75% 100%
0.84  0.89  0.90 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12