/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/06009ET3E405T-W22 WEG 60HP General Purpose Electric Motor, 900RPM

Product ID: 06009ET3E405T-W22

06009ET3E405T-W22 WEG 60HP General Purpose Electric Motor, 900RPM

MFG: WEG Electric Corporation
MFG Part Number: 06009ET3E405T-W22

Selected accessories will also be added to cart
$15,332.25 / Each
Quantity:
IC411 - TEFC, IP55, 404T/405T Frame, 230/460/380VAC 50/60Hz 3 Phase, 11568741, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 2-7/8" Keyed Shaft

Electric Motors

Frame 404/5T
Output 60 HP (45 kW)
Number of Poles 8
Frequency 60 Hz
Rated speed 880 rpm
Slip 2.22 %
Rated voltage 230/460 V
Rated current 146/73.0 A
L. R. Amperes 949/475 A
LRC 6.5x(Code H)
No load current 60.0/30.0 A
Rated torque 358 ft.lb
Locked rotor torque 180 %
Breakdown torque 270 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 40.2 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 60.0 dB(A)
Approx. weight³ 1149 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.0  93.0  93.0 

Power factor

50% 75% 100%
0.68  0.78  0.83 
Frame 404/5T
Output 50 HP (37 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 725 rpm
Slip 3.33 %
Rated voltage 380 V
Rated current 72.9 A
L. R. Amperes 445 A
LRC 6.1x(Code G)
No load current 29.7 A
Rated torque 362 ft.lb
Locked rotor torque 180 %
Breakdown torque 250 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 40.2 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 1149 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  92.1  91.8 

Power factor

50% 75% 100%
0.67  0.79  0.84 
Frame 404/5T
Output 50 HP (37 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 730 rpm
Slip 2.67 %
Rated voltage 400 V
Rated current 70.9 A
L. R. Amperes 475 A
LRC 6.7x(Code H)
No load current 32.0 A
Rated torque 360 ft.lb
Locked rotor torque 210 %
Breakdown torque 290 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 40.2 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 1149 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.9  92.1  91.8 

Power factor

50% 75% 100%
0.64  0.77  0.82 
Frame 404/5T
Output 50 HP (37 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 730 rpm
Slip 2.67 %
Rated voltage 415 V
Rated current 69.2 A
L. R. Amperes 505 A
LRC 7.3x(Code J)
No load current 33.9 A
Rated torque 360 ft.lb
Locked rotor torque 229 %
Breakdown torque 310 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 40.2 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 1149 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.9  92.2  91.8 

Power factor

50% 75% 100%
0.61  0.74  0.81 
Frame 404/5T
Output 60 HP (45 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 720 rpm
Slip 4.00 %
Rated voltage 380 V
Rated current 89.2 A
L. R. Amperes 455 A
LRC 5.1x(Code E)
No load current 29.7 A
Rated torque 438 ft.lb
Locked rotor torque 150 %
Breakdown torque 210 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 40.2 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 1149 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  91.7  90.2 

Power factor

50% 75% 100%
0.74  0.82  0.85 
Frame 404/5T
Output 60 HP (45 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 725 rpm
Slip 3.33 %
Rated voltage 400 V
Rated current 85.0 A
L. R. Amperes 485 A
LRC 5.7x(Code F)
No load current 32.0 A
Rated torque 435 ft.lb
Locked rotor torque 170 %
Breakdown torque 240 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 40.2 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 1149 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  91.7  91.0 

Power factor

50% 75% 100%
0.71  0.80  0.84 
Frame 404/5T
Output 60 HP (45 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 725 rpm
Slip 3.33 %
Rated voltage 415 V
Rated current 82.9 A
L. R. Amperes 514 A
LRC 6.2x(Code G)
No load current 33.9 A
Rated torque 435 ft.lb
Locked rotor torque 190 %
Breakdown torque 260 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 40.2 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 1149 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  91.7  91.0 

Power factor

50% 75% 100%
0.68  0.78  0.83 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12