/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/06018ET3E364T-W22 WEG 60HP General Purpose Electric Motor, 1800RPM

Product ID: 06018ET3E364T-W22

06018ET3E364T-W22 WEG 60HP General Purpose Electric Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: 06018ET3E364T-W22

Selected accessories will also be added to cart
$5,541.75 / Each
Quantity:
IC411 - TEFC, IP55, 364T/365T Frame, 208-230/460VAC 60Hz 3 Phase, 11166654, Foot Mounted, Cast Iron Frame, NEMA Premium Efficiency, 2-3/8" Keyed Shaft

Electric Motors

Frame 364/5T
Output 60 HP (45 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1775 rpm
Slip 1.39 %
Rated voltage 208-230/460 V
Rated current 151-137/68.3 A
L. R. Amperes 1000-902/451 A
LRC 6.6x(Code G)
No load current 41.4-48.0/24.0 A
Rated torque 175 ft.lb
Locked rotor torque 240 %
Breakdown torque 260 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 22.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 922 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.1  94.5  95.0 

Power factor

50% 75% 100%
0.75  0.83  0.87 
Frame 364/5T
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 67.8 A
L. R. Amperes 427 A
LRC 6.3x(Code G)
No load current 23.8 A
Rated torque 176 ft.lb
Locked rotor torque 229 %
Breakdown torque 240 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 22.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 922 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.7  93.9  94.2 

Power factor

50% 75% 100%
0.74  0.84  0.88 
Frame 364/5T
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 65.2 A
L. R. Amperes 450 A
LRC 6.9x(Code G)
No load current 25.3 A
Rated torque 176 ft.lb
Locked rotor torque 250 %
Breakdown torque 280 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 22.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 922 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.3  93.9  94.2 

Power factor

50% 75% 100%
0.70  0.82  0.87 
Frame 364/5T
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 415 V
Rated current 64.3 A
L. R. Amperes 476 A
LRC 7.4x(Code H)
No load current 26.6 A
Rated torque 176 ft.lb
Locked rotor torque 280 %
Breakdown torque 300 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 22.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 922 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.4  94.2  94.3 

Power factor

50% 75% 100%
0.68  0.80  0.86 
Frame 364/5T
Output 60 HP (45 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 380 V
Rated current 83.5 A
L. R. Amperes 434 A
LRC 5.2x(Code E)
No load current 23.8 A
Rated torque 212 ft.lb
Locked rotor torque 190 %
Breakdown torque 200 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 22.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 922 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.1  93.6  93.0 

Power factor

50% 75% 100%
0.80  0.86  0.88 
Frame 364/5T
Output 60 HP (45 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 78.9 A
L. R. Amperes 458 A
LRC 5.8x(Code F)
No load current 25.3 A
Rated torque 211 ft.lb
Locked rotor torque 210 %
Breakdown torque 229 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 22.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 922 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.1  93.6  93.6 

Power factor

50% 75% 100%
0.77  0.84  0.88 
Frame 364/5T
Output 60 HP (45 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 76.5 A
L. R. Amperes 474 A
LRC 6.2x(Code G)
No load current 26.6 A
Rated torque 211 ft.lb
Locked rotor torque 229 %
Breakdown torque 250 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 22.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 922 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.1  94.1  94.1 

Power factor

50% 75% 100%
0.75  0.83  0.87