/Products/Electric Motors/3 Phase Metric/WEG/Foot Mount, W22/15036ET3Y315S/M-W22 WEG 200HP/150kW IEC TRU-Metric Electric Motor, 3600RPM

Product ID: 15036ET3Y315S/M-W22

15036ET3Y315S/M-W22 WEG 200HP/150kW IEC TRU-Metric Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 15036ET3Y315S/M-W22

Selected accessories will also be added to cart
$19,686.75 / Each
Quantity:
IC411-TEFC, IP55, 315S/M Frame, 460/380-415VAC 3-Phase 50/60Hz, 11569172, Foot Mount, Cast Iron Frame, 65mm Keyed Shaft

Electric Motors

Frame 315S/M
Output 200 HP (150 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2985 rpm
Slip 0.50 %
Rated voltage 380 V
Rated current 260 A
L. R. Amperes 2054 A
LRC 7.9
No load current 60.0 A
Rated torque 347 ft.lb
Locked rotor torque 200 %
Breakdown torque 260 %
Locked rotor time 64s (cold) 36s (hot)
Moment of inertia (J) 65.7 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 2616 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.5  96.1  96.2 

Power factor

50% 75% 100%
0.83  0.89  0.91 
Frame 315S/M
Output 200 HP (150 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2985 rpm
Slip 0.50 %
Rated voltage 400 V
Rated current 250 A
L. R. Amperes 1975 A
LRC 7.9
No load current 65.0 A
Rated torque 347 ft.lb
Locked rotor torque 220 %
Breakdown torque 290 %
Locked rotor time 70s (cold) 39s (hot)
Moment of inertia (J) 65.7 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 2616 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  96.1  96.4 

Power factor

50% 75% 100%
0.81  0.88  0.90 
Frame 315S/M
Output 200 HP (150 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2985 rpm
Slip 0.50 %
Rated voltage 415 V
Rated current 241 A
L. R. Amperes 1904 A
LRC 7.9
No load current 70.0 A
Rated torque 347 ft.lb
Locked rotor torque 240 %
Breakdown torque 310 %
Locked rotor time 77s (cold) 43s (hot)
Moment of inertia (J) 65.7 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 2616 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.3  96.1  96.4 

Power factor

50% 75% 100%
0.79  0.87  0.90 
Frame 315S/M
Output 200 HP (150 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3585 rpm
Slip 0.42 %
Rated voltage 460 V
Rated current 219 A
L. R. Amperes 1862 A
LRC 8.5
No load current 60.0 A
Rated torque 289 ft.lb
Locked rotor torque 260 %
Breakdown torque 300 %
Locked rotor time 82s (cold) 46s (hot)
Moment of inertia (J) 65.7 sq.ft.lb
Design N
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2616 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  95.4  95.4 

Power factor

50% 75% 100%
0.79  0.87  0.90 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xM63x1,5 
Terminal Block BMC - 6 pins 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector