/Products/Electric Motors/3 Phase Metric/WEG/Atex, Foot Mount/E0.7518XP3WAX90SF3-W WEG 1HP/0.75kW IEC Metric Explosion Proof Motor, 1800RPM

Product ID: E0.7518XP3WAX90SF3-W

E0.7518XP3WAX90SF3-W WEG 1HP/0.75kW IEC Metric Explosion Proof Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: E0.7518XP3WAX90SF3-W

Selected accessories will also be added to cart
$962.25 / Each
Quantity:
IC411-TEFC, IP56, 90S/L Frame, 220-240/380-415/460VAC 3-Phase 50/60Hz, 13466538, Foot Mount, Cast Iron Frame, 24mm Keyed Shaft

Electric Motors

Frame 90S/L
Output 0.75 kW
Number of Poles 4
Frequency 50 Hz
Rated speed 1440 rpm
Slip 4.00 %
Rated voltage 220/380 V
Rated current 3.06/1.77 A
L. R. Amperes 18.0/10.4 A
LRC 5.9
No load current 1.63/0.946 A
Rated torque 3.67 ft.lb
Locked rotor torque 190 %
Breakdown torque 229 %
Locked rotor time 34s (cold) 19s (hot)
Moment of inertia (J) 0.0911 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 86.6 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
79.1  79.9  79.6 

Power factor

50% 75% 100%
0.62  0.73  0.81 
Frame 90S/L
Output 0.75 kW
Number of Poles 4
Frequency 50 Hz
Rated speed 1445 rpm
Slip 3.67 %
Rated voltage 230/400 V
Rated current 3.01/1.73 A
L. R. Amperes 18.7/10.7 A
LRC 6.2
No load current 1.86/1.07 A
Rated torque 3.66 ft.lb
Locked rotor torque 220 %
Breakdown torque 260 %
Locked rotor time 34s (cold) 19s (hot)
Moment of inertia (J) 0.0911 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 86.6 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
78.0  80.0  80.0 

Power factor

50% 75% 100%
0.59  0.70  0.78 
Frame 90S/L
Output 0.75 kW
Number of Poles 4
Frequency 50 Hz
Rated speed 1450 rpm
Slip 3.33 %
Rated voltage 240/415 V
Rated current 2.99/1.73 A
L. R. Amperes 19.4/11.2 A
LRC 6.5
No load current 2.00/1.16 A
Rated torque 3.65 ft.lb
Locked rotor torque 229 %
Breakdown torque 280 %
Locked rotor time 34s (cold) 19s (hot)
Moment of inertia (J) 0.0911 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 86.6 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
76.9  79.6  80.4 

Power factor

50% 75% 100%
0.55  0.67  0.75 
Frame 90S/L
Output 0.75 kW
Number of Poles 4
Frequency 60 Hz
Rated speed 1750 rpm
Slip 2.78 %
Rated voltage 460 V
Rated current 1.50 A
L. R. Amperes 11.1 A
LRC 7.4
No load current 0.968 A
Rated torque 3.02 ft.lb
Locked rotor torque 250 %
Breakdown torque 320 %
Locked rotor time 34s (cold) 19s (hot)
Moment of inertia (J) 0.0911 sq.ft.lb
Design N
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 51.0 dB(A)
Approx. weight³ 86.6 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
77.0  81.5  82.5 

Power factor

50% 75% 100%
0.54  0.66  0.76 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Space Heater Voltage 200 - 240 V 
Main terminal box hole M25x1,5 
Terminal Block BMC - 6 pins 
Shaft Locking Device Without 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 205P (ISO 12944 - C3) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Joints Seal Lumomoly 
Fan material Aluminum 
Bearing cap Yes- Bearing Cap 
Bolt Material Carbon Steel 
Winding thermal protection Thermistor - 2 wires 1 per phase 150°C 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector