/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/00336ET3E182T-W22 WEG 3HP General Purpose Electric Motor, 3600RPM

Product ID: 00336ET3E182T-W22

00336ET3E182T-W22 WEG 3HP General Purpose Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 00336ET3E182T-W22

Selected accessories will also be added to cart
$572.25 / Each
Quantity:
IC411 - TEFC, IP55, 182T/184T Frame, 230/460VAC 60Hz 3 Phase, 12378662, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 1-1/8" Keyed Shaft

Electric Motors

Frame 182/4T
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3515 rpm
Slip 2.36 %
Rated voltage 230/460 V
Rated current 7.26/3.63 A
L. R. Amperes 62.4/31.2 A
LRC 8.6x(Code K)
No load current 2.60/1.30 A
Rated torque 4.48 ft.lb
Locked rotor torque 250 %
Breakdown torque 360 %
Locked rotor time 50s (cold) 28s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 88.4 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
82.5  86.5  86.5 

Power factor

50% 75% 100%
0.75  0.84  0.88 
Frame 182/4T
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2930 rpm
Slip 2.33 %
Rated voltage 380 V
Rated current 3.09 A
L. R. Amperes 29.7 A
LRC 9.6x(Code L)
No load current 1.25 A
Rated torque 3.58 ft.lb
Locked rotor torque 310 %
Breakdown torque 440 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 88.4 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
81.0  84.5  85.8 

Power factor

50% 75% 100%
0.68  0.79  0.86 
Frame 182/4T
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2940 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 3.00 A
L. R. Amperes 32.1 A
LRC 10.7x(Code M)
No load current 1.35 A
Rated torque 3.57 ft.lb
Locked rotor torque 360 %
Breakdown torque 500 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 88.4 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
80.6  84.5  85.8 

Power factor

50% 75% 100%
0.65  0.77  0.84 
Frame 182/4T
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 415 V
Rated current 2.96 A
L. R. Amperes 32.9 A
LRC 11.1x(Code N)
No load current 1.40 A
Rated torque 3.57 ft.lb
Locked rotor torque 390 %
Breakdown torque 550 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 88.4 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
79.7  84.1  85.9 

Power factor

50% 75% 100%
0.63  0.75  0.82 
Frame 182/4T
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2885 rpm
Slip 3.83 %
Rated voltage 380 V
Rated current 4.34 A
L. R. Amperes 29.5 A
LRC 6.8x(Code H)
No load current 1.25 A
Rated torque 5.46 ft.lb
Locked rotor torque 210 %
Breakdown torque 290 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 88.4 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
84.0  86.5  85.5 

Power factor

50% 75% 100%
0.80  0.87  0.90 
Frame 182/4T
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2900 rpm
Slip 3.33 %
Rated voltage 400 V
Rated current 4.17 A
L. R. Amperes 31.7 A
LRC 7.6x(Code J)
No load current 1.35 A
Rated torque 5.43 ft.lb
Locked rotor torque 240 %
Breakdown torque 330 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 88.4 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
84.0  86.5  85.5 

Power factor

50% 75% 100%
0.77  0.86  0.89 
Frame 182/4T
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2910 rpm
Slip 3.00 %
Rated voltage 415 V
Rated current 4.02 A
L. R. Amperes 32.6 A
LRC 8.1x(Code J)
No load current 1.40 A
Rated torque 5.41 ft.lb
Locked rotor torque 260 %
Breakdown torque 360 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 88.4 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
84.0  86.5  86.5 

Power factor

50% 75% 100%
0.75  0.84  0.88 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Main terminal box hole NPT 1" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 207A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Steel 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap No-Without Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity